Salon Air Quality & Ventilation Code Experts

HealthyAir® Source Capture Fan-Filter Exhauster Multi-Inlet for 2-4 Nail Stations

Designed to Meet IMC Ventilation Code Requirements

The HealthyAir® Source Capture Fan-Filter Exhauster fully complies with, and exceeds, IMC Ventilation Code requirements for Nail Salons. The HA-SCE-G2 model is primarily designed for use as an Outside Ventilation unit, whereby the system is designed to take in contaminated air though the extraction hose, filter contaminants, and discharge treated air out of the facility via an exhaust duct connection to the 5” diameter outlet port of the unit. Air Flow Per Inlet for HA-SCE-G2:

  • Two Inlet:  High 167 CFM / Med 126 CFM / Low 98 CFM
  • Three Inlet:  High 122 CFM / Med 93 CFM / Low 71 CFM
  • Four Inlet:  High 94 CFM / Med 72 CFM / Low 55 CFM

Nation’s Most Trusted Nail Salon Air Quality & Ventilation Code Experts Since 2001

    Coverges:
  • Zone 1
  • Zone 2
  • Zone 3

$1,425.00$2,550.00

SKU: N/A Categories: ,

Clear
Financing
Still Not Sure?

We’re here to help. Schedule a free consultation with an Aerovex expert to help you make the best decision for your salon.

paypal logo
No interest if paid in full within 6 months

On purchases of $99 or more. Check out with PayPal and choose PayPal Credit.
Subject to credit approval.
See Terms. U.S. Customers only.

Aerovex also offers financing.

Call customer service for details at:1.800.288.2023

Additional Product Features & Specifications

Zone 1 – The Source

HealthyAir® Source Capture Fan-Filter Exhauster
Multi-Inlet for 2-4 Nail Stations

Recommend Nail Salon Use

(1) HealthyAir® Source Capture Fan-Filter Exhauster Multi-Inlet system is capable of serving (2-4) adjacent nail stations.

Outside Ventilation – IMC Ventilation Code Compliance

The HA-SCE-G2 model is primarily designed for use as an Outside Ventilation unit, whereby the system is designed to take in contaminated air though the extraction hose, filter contaminants, and discharge treated air out of the facility via an exhaust duct connection to the 4” dia. outlet port of the unit.

The components required to setup the unit for Outside Venting come with the unit, as outlined in the manual.

IMC 2015 Ventilation Code

IMC 2018 Ventilation Code

IMC 2021 Ventilation Code

Weight, Dimensions & Installation

  • The approximate weight and base dimensions of the unit is: 40 lbs. – 12”l x 14”w x 21”h
  • The standard extraction arm hose length is 45”. Custom length hose is available, for information and pricing please contact us.

Operation

  • By easily adjusting the flexible hose, the hoods of the extraction arms can be strategically positioned, approximately 6”-12” from the work area, to capture contaminates from the emission source.
  • The HA-SCE-G2 offers simple remote-control operation and is equipped with a three-speed fan that enables control of air flow and sound level.
  • Maintenance of the unit is simple and does not require the use of any tools.

Filter Model & Replacement

  • The HealthyAir® Source Capture Fan-Filter Exhauster utilizes the model HA-FFM Filter.  Each unit comes with (1) pre-installed filter.
  • The recommend filter replacement cycle is 12 months on average.  However, the need for filter replacement naturally varies depending on the frequency and nature of use.
  • When the unit has been in operation for 400-hours, the Filter Change indicator light, on the Control Panel, will begin to flash. This serves as a reminder to inspect and/or replace the filter.
  • The Filter Change Timer can be reset by following the reset protocol outlined in the manual.
  • The following replacement filter is compatible with this unit: HA-FFM-1111

Airflow per Inlet

Dual Inlet: High: 167 Medium: 126 Low: 98

Triple Inlet: High: 122 Medium: 93 Low: 71

Quad Inlet: High: 94 Medium: 72 Low: 55